• Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network

Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network

Type: Distribution Metering Box
Structure: Protection
Certification: ISO9001:2000, CCC
Form: All- packaged Type
Operation Voltage: Low Voltage
Size: 3 Uint
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
YBM22-12/0.4-1600KVA
Application Range
High-rise Buildings
Shell Material
Steel Plate
Shell Protection Grade
IP34
Brand
Sce
Trademark
SCE
Origin
China
HS Code
8537201000
Production Capacity
980 Sets/Year

Product Description

This series substation follows Standard: GB17467-1998; And relative IEC standard.
This substation is a combination of High Voltage Cabinet, Low Voltage Cabinet and Transformer.
 
Main Technical Parameters for HV Switchgear
No. Item Unit XGN-12(F) XGN-12(F. R) XGN15-12(F) XGN15-12(F. R)
1 Rated Voltage KV 12
2 Rated Insulation Level Rated Short-time Power-frequency Withstand Voltage KV Phase-to-ground Voltage & phase-to-phase Voltage: 42,
Disconnector Break Voltage: 48
Rated Lightning Impulse Withstand Voltage Phase-to-ground Voltage & phase-to-phase Voltage: 75,
Disconnector Break Voltage: 85
3 Rated Frequency Hz 50
4 Rated Current Main Busbar A 630
Load Switch 630 Depend on Fuse 630 Depend on Fuse
5 Rated Current of Fuse A   125   125
6 Rated Short-time Withstand Current   20
7 Rated Peak Withstand Current   50
8 Duration Time of Rated Short-time Withstand Current(Main Loop) S 3 3 3 3
9 Duration Time of Rated Short
time Withstand Current(Grounded Loop)
S 2 2 2 2
10 Rated Short-circuit Making Current KV 50
11 Rated Short-circuit Breaking Current KV   31.5(Prediction)   31.5(Prediction)
12 Rated Breaking Current Active-power Load Current A 630   630  
Close-loop Breaking Current A 630   630  
Cable Charging Current A 10 10 10 10
13 Rated Take-over Current A   3150    
14 Rated Transfer Current A       1700
15 Protection Degree     IP3X
16 Mechanical Endurance Times 1000 2000
Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
256
Year of Establishment
2006-11-09